{"id":13579,"date":"2021-12-21T11:12:53","date_gmt":"2021-12-21T16:12:53","guid":{"rendered":"https:\/\/carleton.ca\/scs\/?page_id=13579"},"modified":"2026-06-02T14:59:22","modified_gmt":"2026-06-02T18:59:22","slug":"honeywell-cp-6-display","status":"publish","type":"page","link":"https:\/\/carleton.ca\/scs\/vintage-computing\/hanging-displays\/honeywell-cp-6-display\/","title":{"rendered":"Honeywell CP-6 display"},"content":{"rendered":"\n<section class=\"w-screen px-6 cu-section cu-section--white ml-offset-center md:px-8 lg:px-14\">\n    <div class=\"space-y-6 cu-max-w-child-5xl  md:space-y-10 cu-prose-first-last\">\n\n            <div class=\"cu-textmedia flex flex-col lg:flex-row mx-auto gap-6 md:gap-10 my-6 md:my-12 first:mt-0 max-w-5xl\">\n        <div class=\"justify-start cu-textmedia-content cu-prose-first-last\" style=\"flex: 0 0 100%;\">\n            <header class=\"font-light prose-xl cu-pageheader md:prose-2xl cu-component-updated cu-prose-first-last\">\n                                    <h1 class=\"cu-prose-first-last font-semibold !mt-2 mb-4 md:mb-6 relative after:absolute after:h-px after:bottom-0 after:bg-cu-red after:left-px text-3xl md:text-4xl lg:text-5xl lg:leading-[3.5rem] pb-5 after:w-10 text-cu-black-700 not-prose\">\n                        Honeywell CP-6 display\n                    <\/h1>\n                \n                                \n                            <\/header>\n\n                    <\/div>\n\n            <\/div>\n\n    <\/div>\n<\/section>\n\n<h2 id=\"honeywell-cp-6\" class=\"wp-block-heading\">Honeywell CP-6<\/h2>\n\n\n\n<p>CP-6 was the university mainframe computer and began operating at Carleton in 1979. Carleton University ran two Honeywell CP-6 mainframe computers, one called PROD for administration (Student Records, Finance, HR, Alumni) and ACAD for the academic computing.&nbsp;Users were able to connect to them using serial connections using the Gandalf PACX front end processors (FEP&#8217;s) (see photo\/framed vintage display). &nbsp;The async card connected terminals and printers to the Honeywell CP-6 mainframe.<\/p>\n\n\n\n<figure class=\"wp-block-image alignnone\"><a href=\"https:\/\/carleton.ca\/scs\/wp-content\/uploads\/sites\/260\/honeywell-cp-6-1600.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"400\" src=\"https:\/\/carleton.ca\/scs\/wp-content\/uploads\/sites\/260\/honeywell-cp-6-1600-400x400.jpg\" alt=\"Honeywell CP-6\" class=\"wp-image-13580\" srcset=\"https:\/\/carleton.ca\/scs\/wp-content\/uploads\/sites\/260\/honeywell-cp-6-1600-400x400.jpg 400w, https:\/\/carleton.ca\/scs\/wp-content\/uploads\/sites\/260\/honeywell-cp-6-1600-160x160.jpg 160w, https:\/\/carleton.ca\/scs\/wp-content\/uploads\/sites\/260\/honeywell-cp-6-1600-240x240.jpg 240w, https:\/\/carleton.ca\/scs\/wp-content\/uploads\/sites\/260\/honeywell-cp-6-1600-768x768.jpg 768w, https:\/\/carleton.ca\/scs\/wp-content\/uploads\/sites\/260\/honeywell-cp-6-1600-1536x1536.jpg 1536w, https:\/\/carleton.ca\/scs\/wp-content\/uploads\/sites\/260\/honeywell-cp-6-1600-200x200.jpg 200w, https:\/\/carleton.ca\/scs\/wp-content\/uploads\/sites\/260\/honeywell-cp-6-1600-360x360.jpg 360w, https:\/\/carleton.ca\/scs\/wp-content\/uploads\/sites\/260\/honeywell-cp-6-1600.jpg 1600w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/a><figcaption class=\"wp-element-caption\">&#8220;FEP (front end processor) circuit card assembly for a Gandalf PACX that connected serial connections from end users. This async card connected terminals and printers to the Honeywell CP-6 mainframe.&#8221;<\/figcaption><\/figure>\n\n\n\n<p>&nbsp;<\/p>\n\n\n\n<p>The CP-6 mainframe was located in Robertson Hall and the ITS Data Center is still located in Robertson Hall today. The photo below is a photo of the donated FEP&#8217;s to the Diefenbunker.<\/p>\n\n\n\n<p>The async cards (vintage display item) were connected to 25 pin serial connectors that were arranged on the back of the FEP.&nbsp; Since there were far more terminals on campus than FEP serial connections, the Gandalf switch was used to share the FEP connections.&nbsp;You can see the monitor and printers on top of the FEP racks.<\/p>\n\n\n\n<p>&nbsp;<\/p>\n\n\n\n<figure class=\"wp-block-image alignnone\"><a href=\"https:\/\/carleton.ca\/scs\/wp-content\/uploads\/sites\/260\/thumbnail_diefenbunker-canada-s-1.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"550\" height=\"413\" src=\"https:\/\/carleton.ca\/scs\/wp-content\/uploads\/sites\/260\/thumbnail_diefenbunker-canada-s-1.jpg\" alt=\"Gandalf PACX\" class=\"wp-image-15826\" srcset=\"https:\/\/carleton.ca\/scs\/wp-content\/uploads\/sites\/260\/thumbnail_diefenbunker-canada-s-1.jpg 550w, https:\/\/carleton.ca\/scs\/wp-content\/uploads\/sites\/260\/thumbnail_diefenbunker-canada-s-1-160x120.jpg 160w, https:\/\/carleton.ca\/scs\/wp-content\/uploads\/sites\/260\/thumbnail_diefenbunker-canada-s-1-240x180.jpg 240w, https:\/\/carleton.ca\/scs\/wp-content\/uploads\/sites\/260\/thumbnail_diefenbunker-canada-s-1-400x300.jpg 400w, https:\/\/carleton.ca\/scs\/wp-content\/uploads\/sites\/260\/thumbnail_diefenbunker-canada-s-1-360x270.jpg 360w\" sizes=\"auto, (max-width: 550px) 100vw, 550px\" \/><\/a><figcaption class=\"wp-element-caption\">Photo of the FEP&#8217;s (front end processors) in a rack with a monitor on top. The equipment was at Carleton University and was donated to the <a href=\"https:\/\/en.wikipedia.org\/wiki\/Diefenbunker\" target=\"_blank\" rel=\"noopener noreferrer\">Diefenbunker<\/a> museum.<\/figcaption><\/figure>\n\n\n\n<h3 id=\"attribution\" class=\"wp-block-heading\">Attribution<\/h3>\n\n\n\n<p>Thank you Greg Schmidt ( School of Business Manager of Computing) and Colin McFadyen (ITS Supervisor of Operations) for their donation and historical input of this vintage computing item.<\/p>\n\n\n\n<h3 id=\"references\" class=\"wp-block-heading\">References<\/h3>\n\n\n\n<p>Honeywell CP-6: <a href=\"https:\/\/en.wikipedia.org\/wiki\/Honeywell_CP-6\" target=\"_blank\" rel=\"noopener noreferrer\">https:\/\/en.wikipedia.org\/wiki\/Honeywell_CP-6<\/a><\/p>\n\n\n\n<p>Gandalf PACX: <a href=\"https:\/\/en.wikipedia.org\/wiki\/PACX\" target=\"_blank\" rel=\"noopener noreferrer\">https:\/\/en.wikipedia.org\/wiki\/PACX<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Honeywell CP-6 CP-6 was the university mainframe computer and began operating at Carleton in 1979. Carleton University ran two Honeywell CP-6 mainframe computers, one called PROD for administration (Student Records, Finance, HR, Alumni) and ACAD for the academic computing.&nbsp;Users were able to connect to them using serial connections using the Gandalf PACX front end processors [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":14449,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_cu_dining_location_slug":"","footnotes":"","_links_to":"","_links_to_target":""},"cu_page_type":[90],"class_list":["post-13579","page","type-page","status-publish","hentry","cu_page_type-vintage-computing"],"acf":{"cu_post_thumbnail":false},"_links":{"self":[{"href":"https:\/\/carleton.ca\/scs\/wp-json\/wp\/v2\/pages\/13579","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/carleton.ca\/scs\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/carleton.ca\/scs\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/carleton.ca\/scs\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/carleton.ca\/scs\/wp-json\/wp\/v2\/comments?post=13579"}],"version-history":[{"count":2,"href":"https:\/\/carleton.ca\/scs\/wp-json\/wp\/v2\/pages\/13579\/revisions"}],"predecessor-version":[{"id":15837,"href":"https:\/\/carleton.ca\/scs\/wp-json\/wp\/v2\/pages\/13579\/revisions\/15837"}],"up":[{"embeddable":true,"href":"https:\/\/carleton.ca\/scs\/wp-json\/wp\/v2\/pages\/14449"}],"wp:attachment":[{"href":"https:\/\/carleton.ca\/scs\/wp-json\/wp\/v2\/media?parent=13579"}],"wp:term":[{"taxonomy":"cu_page_type","embeddable":true,"href":"https:\/\/carleton.ca\/scs\/wp-json\/wp\/v2\/cu_page_type?post=13579"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}